272
Hand-held Analyzer Types 2250 and 2270 – User Manual
B.7 Reverberation Time Measurement
B.7.1 For Reverberation Time Software BZ-7227
The following parameters are measured or calculated at each position:
Decays
• Reverberation Decays (for each frequency band from Bottom Frequency to Top
Frequency) based on sampling L
Zeq
spectra at 5 ms intervals
Spectra
• T30 Spectrum
• T20 Spectrum
• EDT Spectrum
Single Number Values
• T30 (Wide Band RT Bottom – Wide Band RT Top)
• T20 (Wide Band RT Bottom – Wide Band RT Top)
•EDT (Wide Band RT Bottom – Wide Band RT Top)
The following parameters are calculated for the room as an average of all positions:
Decays
• Ensemble Averaged Reverberation Decays (for each frequency band from Bottom
Frequency to Top Frequency)
Spectra
• T30 Spectrum
• T20 Spectrum
• EDT Spectrum
Single Number Values
• T30 (Wide Band RT Bottom – Wide Band RT Top)
• T20 (Wide Band RT Bottom – Wide Band RT Top)
•EDT (Wide Band RT Bottom – Wide Band RT Top)
Quality indicators are given for each frequency band, in each reverberation time spectrum, and
for each reverberation time spectrum.
Instantaneous Measured Parameters (available at any time)
Instantaneous Time-weighted Sound Levels:
•L
AF
•L
CF
Instantaneous Measured Spectra:
•L
ZF
Comentarios a estos manuales