CHAPTER 14
Reverberation Time Software (Optional Module)
159
Fig.14.9
Spectrum table
Auxiliary Parameters
Below the graphics are two lines containing parameters for displaying the wide band reverberation
times for the current position, or the room average. You are also able to display the L
CF
and
L
AF
broadband values.
14.3.3 Decay
The Decay tab shows the reverberation time decay from a position or the room average – or
both (Fig.14.10).
Status Field
The Status Field on the Decay tab is the same as on the Overview and Spectrum tabs.
Decay Graph
The Decay graph shows the decay of one frequency band for the selected position and/or the
decay of the same frequency band for the room average (requires Ensemble Averaging).
The Decay Parameter selectors above the graph select which decay to display: T20@Pos,
T30@Pos or EDT@Pos. Each of these selections show the decay for the measurement at the
selected position together with the readout of T20@Pos, T30@Pos and EDT@Pos resp. T20,
T30 and EDT show the decay for the Room Average together with the readout of T20, T30 and
EDT resp. If you only want one graph you can set the other selector to Off.