Servo Amplier Model SJDE-
-OY
01APA 02APA 04APA 08APA
Max. applicable servo motor capacity W 100 200 400 750
Continuous output current A
rms
0.84 1.1 2.0 3.7
Instantaneous max. output current A
rms
2.5 3.3 6.0 11.1
Input power supply
(for main circuit
and control circuit)
Voltage Single-phase 100 to 115 VAC, +10 to −15% ; Single-phase 200 to 230 VAC, +10 to −15%
Frequency 50/60 Hz ± 5%
Voltage frequency
capacity
at rated output kVA
0.40 0.75 1.2 2.2
Power loss at rated output W 14 16 24 35
Input control method Capacitor-input type, single-phase full-wave rectification with resistance to prevent inrush current
Output control method PWM control, sine wave power driven system
Feedback Incremental encoder
Allowable load inertia*
1
kgm
2
0.6 x 10
-4
3 x 10
-4
5 x 10
-4
10 x 10
-4
I/O signals
Input signal
for reference
(designated
pulse type
and pulse
resolution with
PULSE switch)
Pulse type
Select one of the following settings:
1. CCW + CW pulse train
2. Sign + pulse train
3. CCW + CW pulse train (negative logic)
4. Sign + pulse train (negative logic)
Pulse resolution
Select one of the following settings:
1. 1000 pulses/rev (open collector/line driver) 75 kpps max.
2. 2500 pulses/rev (open collector/line driver) 187.5 kpps max.
3. 5000 pulses/rev (line driver) 375 kpps max.
4. 10000 pulses/rev (line driver) 750 kpps max.
Clear input signal Clears the positioning error at the rising edge of the pulse
Servo ON input signal Turns the servo motor on or off
Alarm output signal OFF if an alarm occurs
Brake output signal External signal to control brakes. Turn ON to release the brake.
Position completed output signal ON if the current position is equal to the reference position ± 10 pulses
Origin output signal ON if the motor is at the origin (width: 1/500 rev)
Built-in functions
Dynamic brake (DB)
Operated at main power OFF, servo alarm, servo OFF
(OFF after motor stops; ON if the motor power is off)
Regenerative processing Optional (if the regenerative energy is too large, install a regenerative unit)
Protection*
2
Speed errors, overload, encoder errors, voltage errors, over currents,
disablement of the built-in cooling fan, system errors
Display Five LED indicators (PWR, REF, AL1, AL2, AL3)
Reference filter Select one of eight levels with FIL switch
Cooling method Forced cooling (built-in fan)
Operating temperature 0 °C to +55 °C
Operating humidity 90% RH or less (no condensation)
Storage temperature –20 °C to +70 °C
Storage humidity 90% RH or less (no condensation)
Installation site Free of corrosive gases; Free of dust and iron powder; Clean and dry
Altitude 1000 m or below
Vibration resistance 4.9 m/s
2
Shock resistance 19.6 m/s
2
Operating conditions
Installation category (overvoltage category): II; Pollution degree: 2
Protection class: IP1X (EN50178)
*
1
Be sure to use the motor within the allowable load moment of inertia. The motor will become unstable if the load moment of inertia exceeds the
allowable value.
*
2
The ground protection circuit is designed for ground fault inside the motor windings while the motor is running. Therefore, it may not protect the
system under the following cases:
A low-resistance ground fault occurs in the main circuit cable or in the connector of the cable for the servo motor.
The power supply is turned on during a ground fault.
Ratings and Specifications